Thermal Energy Storage Tank AWWA D103: Standard for Bolted Steel Tanks

Created on Today
Thermal Energy Storage Tank

Thermal Energy Storage Tank AWWA D103: Standard for Bolted Steel Tanks

AWWA D103-09 governs the design, fabrication and erection of factory-coated bolted steel tanks - the common build for large thermal energy storage tanks. It covers shell, coating, bolts, foundation and acceptance, and pairs with ISO 28765 for the enamel coating system.
AWWA D103-09 is the standard for factory-coated bolted steel tanks, the construction most large thermal energy storage tanks use. Knowing it frames the specification and acceptance.

Technical Explanation

What D103 covers

· It specifies materials, panel design, bolt grades, coating requirements, erection and testing for bolted steel tanks at the relevant pressures.
· It is the contract baseline for bolted TES tanks.

Coating linkage

· The enamel coating is controlled to ISO 28765, which sets thickness, adhesion and holiday testing for the glass-fused layer.
· Two standards, one tank.

Acceptance

· Hydrostatic test, coating holiday test and thickness verification confirm compliance at handover.
· Acceptance makes the standard real.

Technical Specifications

Table 1 - Standards specification factors

Standard
Scope
Use
D103-09
Bolted tank
Build
ISO 28765
Enamel
Coat
Hydro
Test
Proof
Holiday
Test
Coat
Bolts
Grade
Joint

Project Case Study

Project Case Summary - delivered water storage tanks

The deliveries below are representative bolted water and fire-protection storage tanks in glass-fused-to-steel, fusion bonded epoxy and stainless steel construction, with capacity, location and completion date recorded for each order. They illustrate the company's delivered capability for the type of tank discussed in this article.
Project
Application
Capacity
Construction
Roof
Completion
Brazil
Potable water
11,713 m3
Glass-fused-to-steel bolted
Aluminium deck roof
2025
Costa Rica
Potable water
11,756 m3
Glass-fused-to-steel bolted
Aluminium dome roof
2025
Cirebon
Potable water
10,237 m3
Glass-fused-to-steel bolted
Aluminium alloy roof
2020

Company Expertise

Center Enamel (Shijiazhuang Zhengzhong Technology Co., Ltd) manufactures bolted thermal energy storage tanks in glass-fused-to-steel, fusion bonded epoxy and stainless steel, engineered to AWWA D103-09 with the enamel coating process controlled to ISO 28765.
Center Enamel builds bolted thermal energy storage tanks to AWWA D103-09 with enamel coating controlled to ISO 28765.

Frequently Asked Questions (FAQ)

Q: What is AWWA D103-09?
A: The standard for factory-coated bolted steel tanks, common for large TES tanks.
Q: Does it cover coating?
A: It references coating requirements; the enamel detail is in ISO 28765.
Q: Is it mandatory?
A: Where the spec or jurisdiction calls for it; many projects adopt it by reference.
Q: What tests confirm compliance?
A: Hydrostatic test, holiday test and coating thickness verification.
Q: Bolted only?
A: D103 is specifically for bolted steel tanks; welded tanks follow other standards.
Q: Who certifies?
A: The tank is built to the standard; the engineer verifies compliance at acceptance.
AWWA D103-09 is the build standard for bolted thermal energy storage tanks, paired with ISO 28765 for enamel coating. Specifying and testing to it keeps the tank auditable.

Request Technical Specifications

Send your duty, capacity requirement and site conditions, and we will return the tank configuration, coating specification and documentation schedule for your project file.