IFR Vs EFR Vapor Loss: How The Two Roofs Compare
The honest answer to which roof loses less vapour is: it depends on the seal, the fittings and the weather, not on the label internal or external. Under comparable good condition, an internal floating roof (IFR) generally has an advantage because its fixed roof shields the deck and adds a second barrier, while an external floating roof (EFR) is exposed to wind that can carry vapour from the rim. But a well-maintained EFR with a sound dual seal can outperform a poorly maintained IFR, and no universal percentage is defensible. This is comparison reference; Center Enamel does not manufacture floating roofs, and its scope is the tank.
The comparison matters because buyers often quote a single reduction figure for one configuration or the other. That figure is only meaningful against a specific product, diameter, seal condition and climate. Understanding where losses actually occur - the rim gap and the deck fittings - explains why the answer is conditional and why maintenance dominates the result.
Where Floating-Roof Loss Actually Occurs
Both roofs cover the liquid. A floating deck rises and falls with the level, removing the large vapour space that a fixed-roof tank would otherwise breathe. The residual loss is not from the covered surface but from the annular gap at the shell and from penetrations in the deck. Whatever the configuration, those two paths decide performance.
The rim seal is the first path. A gap between deck edge and shell allows vapour to escape, and wind across the deck can carry it away. The seal that closes this gap differs between the two configurations: under 40 CFR Part 60 Subpart Kb an external floating roof must have two seals one above the other, with the primary being a mechanical shoe or liquid-mounted seal, while an internal floating roof may use a single liquid-mounted or mechanical-shoe seal or a vapour-mounted primary with a secondary.
Fittings are the second path. Gauge wells, sample wells, access hatches, vents and sleeves penetrate the deck. The rule requires most to be gasketed and kept closed except in use. A missing gasket or an open cover creates a direct loss path on either roof, and in practice this is a more common cause of high emissions than a dramatic seal failure.
Why Wind Affects The Two Roofs Differently
On an external roof the vapour that escapes the rim is swept away by wind, which sustains the concentration gradient that drives further evaporation. On an internal roof the space above the deck is enclosed by the fixed roof, so escaped vapour accumulates, the gradient falls, and much of it recondenses or is retained. That physical difference, not a marketing claim, is the main reason a well-maintained IFR usually has the edge in loss control.
Comparing The Two Under Like Conditions
To compare fairly, hold the product, diameter, seal condition and climate constant. Both roofs then reduce breathing and working losses dramatically relative to a plain fixed roof, because both remove the free liquid surface. The difference between them is second-order and is dominated by rim-seal condition, fitting integrity and wind exposure. A comparison that changes the product or ignores seal condition is comparing different problems, not different roofs.
Factor | Internal floating roof | External floating roof |
Weather exposure | Deck shielded by fixed roof | Deck open to rain, snow and wind |
Rim seal basis | Single allowed in some frameworks | Dual seal required under Subpart Kb |
Wind-driven rim loss | Low; vapour retained under fixed roof | Higher; wind sweeps escaped vapour |
Fitting loss | Comparable; gasket discipline required | Comparable; gasket discipline required |
Deck drainage | Not a weather-drain case | Drain passes through product to shell outlet |
The governing design standards also differ: API 650 Appendix C addresses external floating roofs and Appendix H addresses internal floating roofs. Note that API 2519 is specifically about evaporating losses from INTERNAL floating roof tanks and is not the right reference for an external roof; EFR vapour control is treated under Subpart Kb and the tank standard. Confirm editions and local adoption.
The Fitting Integrity Factor Is Common To Both
Because both roofs depend on gasketed covers and correctly set vents, fitting discipline is a shared requirement. A buyer comparing configurations should ask the same questions of both: how is each opening sealed, how is it inspected and what is the replacement interval for gaskets. The roof that is better maintained will show lower loss regardless of its label.
Why Condition Outweighs Configuration
The most useful way to read a loss comparison is to separate the design advantage from the maintained condition. An internal roof has a structural advantage because the fixed roof retains escaped vapour and shields the deck from wind, but that advantage is realised only while its seal and fittings are sound. An external roof starts with a greater wind exposure, yet a compliant dual seal in good condition narrows the gap substantially. A buyer who compares a neglected internal roof against a maintained external one will reach the wrong conclusion, and a supplier who quotes a single reduction figure is hiding that dependency.
Operational factors can also reverse the ranking. A tank that is filled and drawn down frequently creates working losses at the rim and fittings on either roof, and the configuration with tighter fitting discipline will perform better regardless of label. A tank in a sheltered location reduces the wind effect on an external roof, while a tank in a hot, windy climate amplifies it. The stored product matters too, because a higher vapour pressure increases the amount of vapour available to escape from the same gap.
For a specification, the practical output is a set of questions rather than a number. Ask the product and vapour pressure range, the site wind and temperature profile, the seal configuration proposed and its inspection interval, and the fitting integrity regime. Require each supplier to explain the loss basis in those terms. An answer grounded in rim condition, fitting discipline and weather is credible; one that offers a universal percentage is not, and it should be treated as a warning about the supplier's understanding rather than as evidence.
What This Comparison Does Not Establish
It does not establish a percentage reduction for either roof, because no transferable figure applies across products, diameters and climates. It does not say that one configuration is always preferable: weather, tank size, product volatility and regulatory context can reverse the choice. The comparison article on configuration choice in the prior IFR batch and the cost articles in this batch take those decisions further.
Claim often heard | What the comparison actually shows |
Internal roofs always emit less | Usually under like condition, but a maintained EFR can outperform a neglected IFR |
External roofs have no vapour control | Both remove the free surface; both control losses through seals and fittings |
A fixed percentage applies | No; loss depends on product, diameter, seal condition, fitting integrity and wind |
The roof type decides compliance | The applicable rule decides the required configuration; condition decides sustained performance |
NFPA 30 provides the flammable-liquids fire context and API 2000 the venting context. Neither sets a loss percentage. The purpose of this article is to explain the mechanism well enough that a buyer can read a supplier's loss claim critically.
How To Use This Comparison In A Specification
State the product and vapour pressure, the site wind and climate, the applicable control framework and the required inspection regime. Ask each supplier to explain the loss basis for the proposed configuration in those terms rather than quoting a generic percentage. The answer will reveal whether they have considered the rim, the fittings and the weather - the three things that actually decide the result.
Bottom Line
An internal floating roof usually has a loss advantage under like conditions because its fixed roof retains escaped vapour and shields the deck from wind. An external floating roof relies on a compliant dual seal and disciplined fittings, and performs well when maintained. Neither label substitutes for condition, and no universal percentage is defensible.
A final practical point is that the two configurations are not substitutes in every tank. A site that already has a fixed roof and needs tighter containment will look to an internal roof; a site building a large new crude tank in a moderate climate will often choose an external roof. The loss comparison is one input to that decision, not the decision itself. Buyers who keep the comparison in that role avoid the error of selecting a roof solely on a loss figure that cannot be transferred between tanks.
The same caution applies to monitoring. Whatever roof is chosen, a loss claim should be tested against the tank's actual breathing pattern and product losses after commissioning. If observed losses exceed expectations, the cause is usually a seal or fitting condition rather than the configuration. A baseline record at handover and a consistent inspection regime are what allow the owner to distinguish a design limitation from a maintenance issue, and to take the right corrective action.
Comparison findings should be recorded with the same discipline as inspection findings. Note the assumptions about product and climate, the condition of each roof at the time and the source of any loss figure. A comparison recorded once can then be revisited when the tank changes service or when new condition data becomes available, instead of being repeated from memory with different conclusions.
Frequently Asked Questions
Which roof loses less vapor?
Under comparable good conditions, an internal roof usually has an advantage because its fixed roof retains vapor and shields the deck from wind. A maintained external roof can outperform a neglected internal roof; no universal percentage applies.
Where do floating-roof losses occur?
Mainly at the rim gap between deck and shell and at deck fittings such as gauge wells, hatches and vents - not from the covered liquid surface.
What does Subpart Kb require for an EFR?
Two seals one above the other, with the primary a mechanical shoe or liquid-mounted seal. Vapour-mounted primary seals are not allowed for external floating roofs.
Is API 2519 the right reference for EFR loss?
No. API 2519 addresses evaporating losses from internal floating roof tanks. EFR vapour control is treated under Subpart Kb and the tank standard.
How does wind change the comparison?
Wind sweeps vapour from an external rim, sustaining evaporation; under a fixed roof escaped vapour accumulates and the gradient falls.
Do fittings matter on both roofs?
Yes. Both depend on gasketed covers and correct vent settings; a missing gasket is a direct loss path on either configuration.
Can I quote a reduction percentage?
Not as a generic figure. It depends on product, diameter, seal and fitting condition and climate; this article publishes none.
What should a specification ask for?
The product and vapour pressure, site climate, applicable rule and inspection regime, plus a loss basis explained in those terms rather than a headline percentage.
Conclusion
Compare IFR and EFR vapour loss by mechanism, not by a headline figure. Both remove the free surface; residual loss comes from the rim and fittings. A fixed roof gives the internal roof a retention advantage, while an external roof depends on a compliant dual seal and disciplined fittings. Condition, product and climate decide the result - not the label.
Work With Center Enamel
Center Enamel's verified product scope is the storage tank that receives a floating roof. It does not manufacture floating roofs and makes no emission-performance or supply claim in that product area.
Center Enamel (Shijiazhuang Zhengzhong Technology Co., Ltd., est. 2008) designs and manufactures GFS, FBE, stainless, galvanized, and welded storage tanks together with aluminum geodesic dome roofs, certified to ISO 9001, ISO 45001, NSF/ANSI 61, EN 1090/CE, WRAS, and FM, with verified deliveries in 100+ countries. This article is buyer/asset-owner engineering reference; no external floating roof case, supply claim or performance figure is made. Center Enamel's verified scope is the tank into which such a roof is installed.