logo.png

sales@cectank.com

86-020-34061629

isiZulu

Ithangi le-GLS: Isitoreji Sensimbi Elineglasi (GFS)

Kwadalwa ngo 09.30
Ithangi le-GLS

Ithangi le-GLS: Insimbi Ene-Glass-Lined (GFS) Yokugcina

Liyini Ithangi le-GLS?

Ithangi le-GLS (ithangi lensimbi eligcotshwe ngengilazi) lisebenzisa ubuchwepheshe obufanayo nethangi le-GFS: amaphaneli ensimbi ane-vitreous enamel ehlanganiswe ku-820–930°C ibe yinhlanganisela engasebenzi futhi emelana nokugqwala. 'GLS' kanye 'GFS' kokubili kuchaza insimbi egcotshwe ngengilazi (ehlanganiswe), futhi la magama asetshenziswa ngokushintshana embonini.

Isebenza Kanjani?

Njengaku-GFS, amaphaneli ayadutshulwa ngezinhlamvu, agcotshwe nge-enamel, ashiswe, bese eboshelwa ndawonye ngamajoyinti ane-gasket ku-ring beam kakhonkolo. Ukugcotshwa kwengilazi kuhlukanisa insimbi endaweni egciniwe, futhi ukuhlolwa kwe-holiday kuqinisekisa ukuthi ukugcotshwa kuqhubeka ngaphambi kokusetshenziswa.

Izinhlobo Eziyinhloko, Izingxenye, Nezici

Ithangi le-GLS eliboshiwe. Ukwakhiwa okujwayelekile kwamanzi/WW/biogas.
I-digester ye-GLS. Ayivumi igesi emsebenzini we-anaerobic.
Izingxenye eziyinhloko: iphaneli eline-enamel, i-gasket, isibophezelo, uphahla, isisekelo, ama-nozzle.

Izicelo

· - Amanzi okuphuza kanye namanzi enqubo- Amanzi angcolile kanye ne-leachate- Ukugaya kwe-anaerobic kanye ne-biogas- Izinqolobane zokuvikela umlilo

Ukucatshangelwa Kwezobuchwepheshe

Izinto zokwakha. Insimbi + i-vitreous enamel lining.
Umthamo. 20–60,000 m³; modular.
Ukugqwala. I-inert glass lining.
Amazinga. ISO 28765, AWWA D103-09, NSF/ANSI 61 wamanzi okuphuza.
Ukufakwa / ukunakekelwa. Phatha amaphaneli; ukugcoba okuncane.
Isikhathi sokusebenza. Iminyaka engama-30+ ebhaliwe.

Isifundo Somklamo

Isifundo Somklamo — eCanada — Amanzi angcolile emfuyo (1248m³, 1, kuqedwa 2025-02)

Isendlalelo Somsebenzi

GLSProject type:GLS Livestock wastewater treatment / anaerobic digestion. GLSIndustry:GLS Livestock / agriculture. GLSLocation:GLS Canada. GLSApplication:GLS Livestock wastewater storage / treatment. GLSObjective:GLS provide a reliable, standards-referenced above-ground containment with controlled quality and a practical erection schedule.

Izidingo Zephrojekthi

- GLSStorage capacity:GLS 1248m³
- GLSQuantity:GLS 1
- GLSTank size:GLS φ13.76×8.4 m(H) 1 unit
- GLSStorage medium:GLS Livestock wastewater
- GLSApplicable standards:GLS ISO 28765, AWWA D103-09
- GLSSite limitation:GLS controlled quality, practical schedule

Izinselelo Zobuchwepheshe

Umsebenzi wawudinga ivolumu enkulu, ehambisana nekhodi enekhwalithi engancikile ekushiseleni kwensimu okuguquguqukayo. Uhlelo oluboshwe ngamabhawudi olulawulwa yifekthri lunciphisa izinguquko zasendaweni ekhwalithini yokumboza kanye namalunga.

Ubunjiniyela / Isixazululo Somkhiqizo

- Uhlobo lwe-GLSTank: I-GLS Glass-Fused-to-Steel (GFS) ithangi eliboshwe ngamabhawudi
- Impahla ye-GLS: Amaphaneli ensimbi ye-carbon ephansi ye-GLS anokumbozwa kwe-vitreous enamel okuhlanganiswe ku-820–930°C
- Uphahla lwe-GLS: I-GLS Akucacisiwe kurekhodi enikeziwe
- Ukuhlelwa kwesakhiwo se-GLS: Igobolondo lamaphaneli aboshwe ngamabhawudi phezu kwesikhungo sikakhonkolo esinamalunga ane-gasket
- Isisekelo se-GLS: Isikhungo sikakhonkolo esakhiwe ngobunjiniyela esinamabhawudi okubopha
- Izindinganiso ezisetshenzisiwe ze-GLS: I-GLS ISO 28765, AWWA D103-09

Ukuqaliswa Komsebenzi

Amaphaneli enziwa futhi (kwe-GFS) afakwa i-shop-enamel ngaphansi kokulawulwa kwekhwalithi yasefekthri, abese ethunyelwa ukuze amiswe ngamabhawudi endaweni. Amajoyinti ane-gasket kanye nezibophezelo zesakhiwo zafakwa ngokwenqubo futhi zahlolwa ngokohlelo lwekhwalithi lwephrojekthi. (Izinyathelo ezithile zokuqalisa ngaphandle kwerekhodi elinikeziwe azishiwo.)

Umphumela Wephrojekthi

- Isimo se-GLS: I-GLS Iqediwe (2025-02)
- Umthamo we-GLS Otholakele: I-GLS 1248m³ kuyo yonke i-1
- GLSOutcome: Isitoreji sangaphezulu somhlabathi se-GLS sinikezwa njengohlelo oluboshiwe, olubhekisela emazingeni
Ulwazi Lwephrojekthi
Imininingwane
Uhlobo Lwephrojekthi
Ukuhlanza amanzi angcolile emfuyo / ukugaya i-anaerobic
Indawo
E-Canada
Imboni
Imfuyo / ezolimo
Ukusetshenziswa
Ukugcinwa / ukwelashwa kwamanzi angcolile emfuyo
Umkhiqizo
Ithangi elihlanganisiwe le-Glass-Fused-to-Steel (GFS) eliboshwe ngamabhawudi
Umthamo
1248m³
Inani
1
Impahla
Glass-Fused-to-Steel (GFS)
Amazinga
ISO 28765, AWWA D103-09
Isimo sePhrojekthi
Kuqediwe (2025-02)

Isithenjwa Esengeziwe — i-Namibia — Amanzi okuphuza (44900m³, 4, kuqediwe 2022-09)

Isendlalelo sePhrojekthi

Uhlobo lwePhrojekthi ye-GLS: Ukugcinwa kwamanzi okuphuzwayo kwe-GLS. Imboni ye-GLS: Ukuhlinzekwa kwamanzi kamasipala kwe-GLS. Indawo ye-GLS: i-Namibia. Ukusetshenziswa kwe-GLS: Ukugcinwa / ukwelashwa kwamanzi okuphuzwayo. Inhloso ye-GLS: ukuhlinzeka ngendawo yokugcina engaphezulu komhlaba ethembekile, ebhekiselwe emazingeni, enekhwalithi elawulwayo kanye nohlelo lokwakha olusebenzayo.

Izidingo zePhrojekthi

- Umthamo wokugcina we-GLS: 44900m³
- GLSQuantity:GLS 4
- GLSTank size:GLS φ41.26×8.4 m(H) 4 unit
- GLSStorage medium:GLS Drinking water
- GLSApplicable standards:GLS NSF/ANSI 61, ISO 28765, AWWA D103-09
- GLSSite limitation:GLS controlled quality, practical schedule

Izinselele Zobuchwepheshe

Umsebenzi wawudinga ivolumu enkulu, ehambisana nekhodi enekhwalithi eyayinganciki ekushiseleni kwensimu okuguquguqukayo. Uhlelo oluboshiwe olulawulwa efektri lunciphisa izinto eziguquguqukayo endaweni ekufakweni nasekhwalithini yamalunga.

Isixazululo Sobunjiniyela / Somkhiqizo

- GLSTank type:GLS Glass-Fused-to-Steel (GFS) bolted tank
- GLSMaterial:GLS low-carbon steel panels with vitreous enamel coating fused at 820–930°C
- GLSRoof:GLS Aluminum flat roof
- GLS Ukuhlelwa kwesakhiwo: iphaneli ye-GLS eboshwe ngezibhawodi kusihlalo sokhonkolo kakhonkolo esinamajoyinti ane-gasket
- GLS Isisekelo: isihlalo sokhonkolo kakhonkolo esakhiwe nge-GLS esinamabhawodi okubopha
- GLS Amazinga asetshenzisiwe: i-GLS NSF/ANSI 61, ISO 28765, AWWA D103-09

Ukuqaliswa Komsebenzi

Amaphaneli enziwa futhi (kuma-GFS) afakwa i-enamel esitolo ngaphansi kokulawulwa kwekhwalithi yasefekthri, abese ethunyelwa ukuze amiswe ngokuboshwa endaweni. Amajoyinti ane-gasket nezinto zokubopha zesakhiwo zafakwa ngokwenqubo futhi zahlolwa ngokohlelo lwekhwalithi lwephrojekthi. (Izinyathelo eziqondile zokuqalisa umsebenzi ezingaphezu kwerekhodi elinikeziwe azishiwo.)

Umphumela Wephrojekthi

- GLSIsimo: GLS Kuqediwe (2022-09)
- GLSAmandla afinyelelwe: GLS 44900m³ kuzo zonke ezi-4
- GLSImiphumela: GLS ukugcinwa kwangaphezulu komhlaba kunikezwe njengohlelo oluboshiwe, olubhekiselwe emazingeni
Ulwazi Lwephrojekthi
Imininingwane
Uhlobo Lwephrojekthi
Ukugcinwa kwamanzi aphuzwayo
Indawo
INamibia
Imboni
Ukunikezwa kwamanzi kamasipala
Ukusetshenziswa
Ukugcinwa / ukwelashwa kwamanzi okuphuza
Umkhiqizo
Ithangi eliboshiwe le-Glass-Fused-to-Steel (GFS)
Umthamo
44900m³
Ubuningi
4
Impahla
Glass-Fused-to-Steel (GFS)
Amazinga
NSF/ANSI 61, ISO 28765, AWWA D103-09
Isimo Sephrojekthi
Kuqediwe (2022-09)

Izinzuzo Nemikhawulo

Izinzuzo

· - Ukufakwa okungasebenzi — kubushelelezi, akunazimbobo - Ukumelana nokugqwala — ingilazi efanayo - Ukulawula kwesitolo — ukushisa okungaguquki - Okusheshayo, okungahambiswa — amaphaneli aboshiwe

Imikhawulo

· - Ukuqhekeka — amaphaneli aphathwa ngokucophelela - Ukulungisa — inqubo ye-enamel ehambisanayo - Izinga lokushisa — ngaphansi kwezinga lokushisa eliphezulu lensimbi - Akukona konke — amanye amakhemikhali adinga i-FRP

Ukuqhathaniswa Kwezinhlobo Zamathangi Afanele

Umbandela
GLS (GFS)
I-Epoxy Coated
I-Stainless
Ayisebenzi
Yebo (ingilazi)
Cha (ifilimu)
Yebo
Umthamo
20–60,000 m³
Kuyafana
Encane–phakathi
Iphuzwayo
NSF/ANSI 61
Kuncike esitifiketini
Yebo
Kuhle kakhulu ku-
Amanzi, WW, i-biogas
Amakhemikhali amnene
Inhlanzeko/okuhlaselayo

Ungakhetha kanjani isisombululo esifanele

· - Okulingene — qinisekisa ukuhambisana kwe-glass-lining- Ukugunyazwa — NSF/ANSI 61 yamanzi okuphuza- Ikhwalithi — ukuhlolwa kwe-holiday, idatha yokunamathela- Amazinga — ISO 28765 / AWWA D103-09- Ukuphatha — ukumiswa kuvikela i-lining- Izinkomba — amaphrojekthi e-GLS afanayo
Ukukhethwa kwe-GLS Tank kufanele kulandele indlela egciniwe, umthamo, amazinga, kanye nezithiyo zendawo. Isipiliyoni sephrojekthi esiqinisekisiwe kanye nekhwalithi ebhaliwe (i-coating, i-holiday-test, kanye namarekhodi okunamathela) kubaluleke kakhulu kunezimangalo zokumaketha lapho kucaciswa ukufakwa okuhlala isikhathi eside, okuhambisana nemithetho.
Ukuze kutholakale ukusekelwa kwemininingwane, i-Center Enamel inikeza ukufakwa kwama-GLS Tank okubhekiselwe kukho, ubufakazi bokuhlolwa kweholide nokunamathela, kanye nezilinganiso zesabelomali.

Imibuzo Evame Ukubuzwa (FAQ)

Yini ithangi le-GLS?

Ithangi le-GLS (insimbi ene-glass-lined) liyafana nethangi le-GFS: amaphaneli ensimbi ane-vitreous enamel ehlanganiswe ku-820–930°C ibe yinhlanganisela engasebenzi futhi engagqwali. 'GLS' kanye 'GFS' amagama ashintshana.
I-Center Enamel ingaqinisekisa izimvume ezisebenzayo futhi yabelane ngezinkomba zokufakwa kwama-GLS Tank okufanayo.

Ingabe i-GLS iyafana ne-GFS?

Yebo — insimbi ene-glass-lined kanye ne-glass-fused-to-steel kuchaza ubuchwepheshe obufanayo be-vitreous-enamel-on-steel; izifinyezo ziyahluka ngesifunda nangomkhuba.
I-Center Enamel isekela i-GLS Tank ngokwenza i-enamel yasefektri, ukuhlolwa kwabantu besithathu, kanye nokulethwa kwephrojekthi emhlabeni wonke.

Amathangi e-GLS asetshenziselwani?

Amanzi okuphuza nawokucubungula, amanzi angcolile kanye ne-leachate, ukugaya i-anaerobic ne-biogas, kanye nezinqolobane zokuvikela umlilo.

Ingabe amathangi e-GLS avunyelwe emanzini okuphuza?

Yebo — ukufakwa kwengilazi akunamsindo futhi amasistimu anikezwa ngomsebenzi wokuphuza ngemvume ye-NSF/ANSI 61, WRAS, noma i-ACS kuye ngemakethe.

Ithangi le-GLS lihlala isikhathi esingakanani?

Ukusebenza okubhaliwe kweminyaka engama-30+ kuvamile lapho amarekhodi okuhlolwa kweholide nokunamathela egcinwa futhi amaphaneli aphathwa ukuze kugwenywe ukuqhekeka.
Sitshele indlela yakho, umthamo, kanye nemakethe yemvume; sizocacisa ithangi le-GLS (GFS) elinemibhalo yokuhlolwa kweholide.
Xhumana ne-Contact Center Enamel ukuze uthole ukubuyekezwa kwencazelo kanye nesilinganiso sesabelomali kuphrojekthi yakho ye-GLS Tank.
WhatsApp