logo.png

sales@cectank.com

86-020-34061629

Ўзбек тили

Sig'imni Kengaytirish Uchun Keyinchalik Tanklar Qo'shilishi Mumkinmi: Boltli Qobiq va Panel Doirasi

Tashkil Topildi 09.07

Saqlash tanklarini keyinroq qo'shish: Bosqichma-bosqich quvvatni kengaytirish

Keyinchalik sig'imni kengaytirish uchun tanklar qo'shilishi mumkinmi: murvatli qobiq va panel doirasi

Bolted glass-fused-to-steel tanks can be enlarged after commissioning by adding panels to raise the shell, adding courses to extend the height, or installing a second tank alongside the first. Each route depends on something decided at the start: the concrete ring beam must be founded and reinforced for the taller shell or the new tank load, the original shell plate schedule must allow an additional course, and the roof and nozzles must be selected so they can be unbolted and refitted. Capacity calculated from diameter and height, so expanding height is usually the cheapest route where the pad allows.
Савол энг нокулай паллада келади — одатда биринчи систерна ишга туширилганидан икки йил ўтиб, ишлаб чиқариш линиясидаги тўсиқлар бартараф этилиб, энди омбор чекловга айланган пайтда. У пайтга келиб майдонча қотиб бўлган, қувурлар тортилган ва операторлар балансни ушлаб туриш учун сатҳни паст сақлашни ўрганиб олган бўлади. Ҳақиқий жавоб шуки, болтли систерналар чиндан ҳам кенгайтирилади, аммо кенгайтириш ишга тушириш пайтида лойиҳалаштирилиши керак ва бунинг учта усули — қобиқни кўтариш, систерна қўшиш ёки иккаласини қўшиш — жуда фарқли харажатлар ва жуда фарқли шартларга эга. Дастлабки буюртмада банд сифатида ёзилса, ўша савол қуйидагича бўлади: қувватни кенгайтириш учун кейинроқ систерналар қўшиш мумкинми? Бу банд бўлмаса, объектдаги жавоб одатда йўқ бўлади.
Ko'proq sig'imga uchta yo'l
Balandlik odatda eng arzon kengaytirish usuli bo'lib, u ko'pincha dastlabki loyihada e'tibordan chetda qoladi. Boltli rezervuar zavodda tayyorlangan taxminan 1,2 m kenglikdagi panellar va 8,8-darajali boltlardan yig'iladi, shuning uchun qo'shimcha qator qo'shish qo'shimcha qoplangan panellarni yetkazib berish, mavjud yuqori birikmaga yangi qistirma o'rnatish va kengaytirish halqasini o'rnatishdan iborat. Bu faqat dastlabki qobiq plastinasi jadvali qo'shimcha qator uchun qalinlik zaxirasini qoldirgan va poydevor qo'shilgan yukni ko'tarish uchun quyilgan hollarda ishlaydi, shuning uchun halqa to'sinining qalinligi, anker boltlar sxemasi va cho'kish toleransi birinchi kundan chizmada bo'lishi kerak. Ikkinchisi — yostiq yo'li: birinchisining yoniga ikkinchi rezervuar o'rnatish va ikkalasini bir xil nasos va sath nazoratiga ulash, bu odatda balandlik kran yoki qo'shni bino bilan cheklangan hollarda yechim bo'ladi. Uchinchisi — aralash: mavjud yostiqda balandroq qobiq va mavsumiy cho'qqi uchun kichikroq rezervuar.
Poydevor - bu asosiy cheklovchi omil
Hajmi kattalashgan rezervuar poydevor muammosini ham keltirib chiqaradi. Har bir qoʻshimcha metr qobiq ogʻirlik, shamol maydoni va agʻdaruvchi momentni oshiradi, boltli panel tizimi esa bularning barchasini qobiq tubi orqali beton halqali toʻsinga yoki oddiy beton poydevorga uzatadi. Agar halqali toʻsin qurilgan balandlik uchun loyihalashtirilgan boʻlsa va maydoncha allaqachon biroz choʻkkan boʻlsa, qobiqni koʻtarish pastki qatorlardagi termoyadroviy chokni ochishi mumkin, emal esa deformatsiyaga bardosh bera olmaydi. Oldindan tortilgan yoki qalinlashtirilgan halqali toʻsinlar, kelgusi qatorlar uchun qoʻshimcha uzunlikda yoki tasdiqlangan gilza bilan quyilgan anker boltlar va kelishilgan choʻkish chegarasi boshida juda kam xarajat talab qiladi va butun yangilanishni saqlab qoladi. Agar kengaytirish umuman ehtimol boʻlsa, buni soʻrovda aytib oʻting.
Keyinchalik qo'shib bo'lmaydigan narsa
Ba'zi elementlar amalda bir martalik qarorlardir. Poydevor va uning ankraj joylashuvi eng aniq misoldir. Bundan tashqari, tom ham muhim: AWWA D108 va API 650 standartlariga hamda ADM 2015 va ASCE 7-10 bo'yicha shamol va qor yuklamasiga asoslangan alyuminiy gumbaz ma'lum bir oraliq va ma'lum bir rezervuar usti uchun loyihalanadi, shuning uchun balandroq qobiq odatda balandroq gumbaz emas, balki yangi gumbaz talab qiladi va yuqori qavat yangi gumbaz unga o'rnashadigan qilib detallashtirilishi kerak. Shtutserlar, lyuklar, aralashtirgich o'tkazgichlari va gaz yig'ish qalpog'i yoki uch fazali separator kabi har qanday ichki texnologik armaturalar dastlabki panel joylashuvida mavjud bo'lishi shart, chunki boltli panellar ular atrofida zavodda tayyorlanadi; keyinchalik shtutser qo'shish qoplangan plastinani qurilish maydonchasida kesishni anglatadi, bu esa modifikatsiya emas, balki nuqson va oqish xavfidir. Shamollatish va bosimdan bo'shatish tartibi, hamda digestorlar uchun bosim konverti ham gaz bo'shlig'i o'zgarganda qayta ko'rib chiqilishi kerak.
Sig'im raqami qayerdan kelib chiqadi
Kengaytirishni rejalashtirish hajm tenglamasidan boshlanadi va bu diametr hamda balandlik masalasidir. Ish hajmi — bu rezervuar maydonining foydali suyuqlik balandligiga ko‘paytmasi, shuning uchun berilgan poydevor maydoni uchun balandlik eng kam qo‘shimcha xarajat dastagi hisoblanadi, berilgan balandlik uchun esa diametr eng kam gidravlik bosim dastagidir. Bu yerda sig‘im bilan tanishlik yordam beradi: oiladagi katta diametrli boltli rezervuar 44 900 m³ hajmda yetkazib berilgan, alohida rezervuarlar esa 60 000 m³ gacha yetkazib beriladi, shuning uchun faqat balandlik hisobiga kengaytirishning yuqori chegarasi real, ammo keng imkoniyatdir. Bu yuqori chegaradan tashqarida to‘g‘ri yechim — haddan tashqari bitta idish emas, balki ikkinchi rezervuar, chunki juda baland qobiq saqlash hajmini oshirgandan ko‘ra poydevor va shamol yuklamasini tezroq oshiradi.
Texnik spetsifikatsiya
Parametr
Odatiy qiymat / diapazon
Izoh
Panel kengligi
~1,2 m
Zavodda tayyorlangan murvatli panel, kengaytirish sxemasining asosi
Devor plastinkasi qalinligi
Loyiha bo'yicha 3–12 mm
Qo'shimcha qatlamlar faqat jadvalda joy bo'lsa mumkin
Boltli ulash
8.8 darajali boltlar
Yangi qatlamlar qo'shilganda qayta tortiladi
Qistirma
Har bir gorizontal birikmada EPDM
Har bir kengaytirish birikmasida almashtiriladi
Poydevor
Beton halqa to'sin yoki oddiy beton
Kengaytirilgan yuk va cho'kish uchun mo'ljallangan bo'lishi kerak
Tomga oid ma'lumot
AWWA D108 / API 650
Agar kerak bo'lsa, yangi tank balandligi uchun gumbaz almashtiriladi
Shamol va qor yuki
ADM 2015 / ASCE 7-10
Balandroq qobiqning yuqori qatlami va gumbazini boshqaradi
Emal qatlami
820–930 °C da birlashtirilgan 0.25–0.45 mm
3,450 N/cm² dan yuqori baholangan
Uchqun testi
1500 V DC
Barcha yangi panellarda har bir plastinkani tekshirish
Bitta tank chegarasi
60 000 m³ gacha
Buning ortidan ikkinchi tank mantiqiy javob bo'ladi
Ishlayotgan maydonchada kengaytirishni rejalashtirish
Har bir yoʻnalishga kirishishdan oldin beshta tekshiruv. Mavjud poydevordagi qolgan zaxira yukni va maydonchaning choʻkish tarixini tasdiqlang. Rezervuar usti konfiguratsiyasini va gumbaz yoki tomni qayta ishlatish mumkinmi yoki almashtirish kerakmi, aniqlang. Mavjud kran balandligini va 1,2 m panellarni yetkazib berish uchun maydonga kirish imkoniyatini tasdiqlang, chunki ishlab turgan rezervuar ustidan baland koʻtarish toʻxtatish masalasidir. Texnologik tomonni tasdiqlang: sath nazorati, nasos quvvati va agar digestor yoki yopiq rezervuar boʻlsa, gaz bilan ishlash, chunki rezervuar quvurlardan osonroq. Va toʻxtatish oynasini tasdiqlang — ishlab turgan rezervuarda qobiqni koʻtarish bosqichma-bosqich ish, dam olish kunlik ish emas.
Loyiha misoli
Loyiha
Joylashuv
Mahsulot
Sig'im
Qamrov
Katta diametrli boltli suv idishi
Namibiya
GFS tanki
44 900 m³
Yetkazib berish va nazorat, katta diametrli yetkazib berish
Yong'in suvi saqlash, ikkita tank
Sichuan, Xitoy
GFS rezervuari
8,930 m³ (ikkita rezervuar, diametri taxminan 19,87 m va balandligi 14,4 m)
Parallel kengaytirishni ko'rsatuvchi ko'p rezervuarli ta'minot
Sanoat oqava suv rezervuarlari
Xinjiang, Xitoy
GFS rezervuarlari
27 ta rezervuar bo'ylab 30,469 m³
Takrorlanadigan ko'p birlikli yetkazib berishni tasdiqlovchi partiyaviy ta'minot
Shahar oqava suv rezervuarlari
Sichuan, Xitoy
GFS rezervuarlari
10 ta rezervuar bo'ylab 17,420 m³
Ko'p rezervuarli shahar dasturi
Ichimlik suvi saqlash
Indoneziya
GFS tank
21,099 m³ (diametri taxminan 42.04 m, balandligi 15.2 m)
Katta diametrli yagona idish
Center Enamel muhandislik salohiyati
Center Enamel (Shijiazhuang Zhengzhong Technology Co., Ltd) 2008-yildan buyon boltli saqlash tanklarini loyihalashtiradi va ishlab chiqaradi. Xitoyning birinchi shisha-emal po‘lat (GFS) tank ishlab chiqaruvchisi sifatida kompaniya emalga oid 200 ga yaqin patentga ega bo‘lib, yiliga taxminan 300 000 dona emal qoplangan po‘lat plastina ishlab chiqaradi, 30 000 dan ortiq o‘rnatilgan loyihalarni yakunlagan va tanklarini 100 dan ortiq mamlakatga yetkazib beradi. Ishlab chiqarish quvvatini oshirish uchun yangi 150 000 m² ishlab chiqarish bazasi qo‘shildi va bitta tanklar 60 000 m³ gacha yetkazib beriladi. Ishlab chiqarish ISO 9001 va ISO 45001 asosida amalga oshiriladi, mahsulot sertifikatlari NSF/ANSI 61, WRAS, FDA, LFGB, CE (EN 1090), ISO 28765, FM, BSCI va EUROCODE ni o‘z ichiga oladi, loyihalash esa qo‘llanilish talab qilganda AWWA D103-09, AWWA C550 va NFPA ga asoslanadi.
Bu mahsulot oilasining asosiy jihati murvatli konstruktsiya bo'lgani uchun, bu kengaytirish uchun dizayn tekshiruvlarini qamrab oladi, bu esa tankni keyinchalik quvvatni oshirish uchun qo'shish imkonini beradi — poydevor yuklanishi, ankraj joylashuvi, qo'shimcha qatlamlar va tomni almashtirish — ikkinchi birlik buyurtma qilinishidan ancha oldin.
Ko'p beriladigan savollar
1-savol: Tugallangan murvatli tankni shunchaki balandroq qilish mumkinmi?
A1: Ha, agar ikkita narsa rejalashtirilgan bo'lsa. Qobiqning pastki qismlarida qo'shimcha qator uchun plastinka qalinligi uchun joy bo'lishi kerak va poydevor qo'shilgan og'irlik va shamol maydonini ko'tara olishi kerak. Bu ikkisi mavjud bo'lsa, panellarni qo'shish yangi qistirma birikmasi bilan bosqichma-bosqich murvat bilan mahkamlashdir.
Q2: Quvvatni qo'shishning eng arzon usuli qanday?
A2: Odatda mavjud poydevor ustidagi balandlik, chunki u poydevor va maydonchadan qayta foydalanadi va faqat panellar, qator halqasi va yangi tom yoki gumbaz kengaytmasini qo'shadi. Ikkinchi tankni birinchisining yoniga qo'shish, kran balandligi yoki kirish ko'tarishni cheklaydigan juda baland qobiqdan ko'ra odatda arzonroqdir.
Q3: Bitta tank qanchalik katta bo'lishi mumkin?
A3: Ushbu mahsulot oilasida bitta rezervuarlar 60 000 m³ gacha yetkazib beriladi. Bundan ortiq hajmlarda poydevor, shamol yuki va tomning muhandislik xarajatlari saqlash hajmidan tezroq oshadi va odatda ikkinchi rezervuar eng yaxshi yechim bo‘ladi.
Q4: Ishga tushirgandan keyin nozul yoki aralashtirgich qo'shishim mumkinmi?
A4: Toza emas. Boltli panellar zavodda tayyorlanadi, shuning uchun qo'shilgan nozul qoplangan plastinani joyida kesish va qoplama hamda holiday testini tiklashni anglatadi. Aralashtirgichlar, lyuklar va jarayon ichki qismlari uchun teshiklar asl panel tartibida bo'lishi kerak.
Q5: Balandroq qobiq tomga talabni o'zgartiradimi?
A5: Ha. Alyuminiy gumbaz ma'lum bir oraliq va shamol hamda qor yuklamasi ostida tank tepasi uchun ADM 2015 va ASCE 7-10 asosida loyihalanadi. Sezilarli darajada balandroq qobiq odatda yangi balandlikka moslashtirilgan yangi gumbazni anglatadi, shuning uchun asl gumbaz detali qayta ishlatish uchun ko'rib chiqilishi kerak.
Q6: Agar kengaytirish ehtimoli bo'lsa, ishlab chiqaruvchiga nima aytishim kerak?
A6: Buyurtma berilishidan oldin buni ayting. Halqa to'sin kesimi, anker bolt uzunligi yoki gilza ta'minoti, plastina qalinligi jadvali va yuqori qatlam detali — bularning barchasi kelajakdagi balandlik ma'lum talab bo'lganda o'zgaradi va ularni boshida kiritish arzon.
Q7: Qaror qabul qilishdan oldin mavjud poydevorni tekshirish mumkinmi?
A7: Ha. cho'kish tarixi, halqa to'sin kesimi va quyilgan anker joylashuvi har qanday taklifdan oldin ko'rib chiqilishi mumkin. Ko'p hollarda muhandis chizma va uchastka yozuvlaridan qo'shimcha qatlamning maqsadga muvofiqligini va qancha poydevor ishi talab qilinishini ayta oladi.
Bolted saqlash rezervuarlari haqiqatan ham o'sishi mumkin bo'lgan kam sonli idishlardan biridir: panellar, qatorlar va ikkinchi bloklar almashtirish emas, balki qo'shimchalar hisoblanadi. Bu moslashuvchanlikning narxi spetsifikatsiya vaqtida, poydevor qismida, anker joylashuvida va plastina jadvalida to'lanadi. Balandlik odatda eng arzon yo'l, ikkinchi rezervuar odatda eng xavfsiz yo'l, tom va o'tkazgichlar esa panel ro'yxati qotib qolishidan oldin o'ylab chiqilishi kerak. Agar kengaytirish ehtimoli bo'lsa, bu imkoniyatni dastlabki so'rovda yozma ravishda ko'rsating — bu butun loyihadagi eng arzon qarordir.
Muhandis bilan gaplashing
Bizga hozirgi tank diametri va balandligi, poydevor holati va cho'kish tarixi, qo'shimcha balandlik yoki ikkinchi blokni tortish- tortmasligingiz, mavjud kran balandligi va uch yildan keyin kerak bo'ladigan sig'im haqida ma'lumot bering. Biz marshrut taqqoslash, poydevor yuklamasini tekshirish, anker va kengaytirish halqasi bo'yicha tavsiyalar hamda qo'shimcha uchun chizmalar va spetsifikatsiyani taqdim etamiz. Avvalo muhandislik, hech qanday majburiyatsiz va raqamlar tasdiqlanmaguncha tijoriy suhbat yo'q.
WhatsApp